private void VerifyRopFastTransferDestinationConfigureResponse(RopFastTransferDestinationConfigureResponse ropFastTransferDestinationConfigureResponse, byte outputHandleIndex)
{
// Add the debug information
Site.Log.Add(LogEntryKind.Debug, "Verify MS-OXCROPS_R3667");
// Verify MS-OXCROPS requirement: MS-OXCROPS_R3667
Site.CaptureRequirementIfAreEqual<Type>(
typeof(byte),
ropFastTransferDestinationConfigureResponse.RopId.GetType(),
3667,
@"[In RopFastTransferDestinationConfigure ROP Response Buffer] RopId (1 byte): An unsigned integer.");
// Add the debug information
Site.Log.Add(LogEntryKind.Debug, "Verify MS-OXCROPS_R3669");
// Verify MS-OXCROPS requirement: MS-OXCROPS_R3669
Site.CaptureRequirementIfAreEqual<byte>(
(byte)RopId.RopFastTransferDestinationConfigure,
ropFastTransferDestinationConfigureResponse.RopId,
3669,
@"[In RopFastTransferDestinationConfigure ROP Response Buffer, RopId (1 byte):] For this operation [RopFastTransferDestinationConfigure] this field is set to 0x53.");
// Add the debug information
Site.Log.Add(LogEntryKind.Debug, "Verify MS-OXCROPS_R3670");
// Verify MS-OXCROPS requirement: MS-OXCROPS_R3670
Site.CaptureRequirementIfAreEqual<Type>(
typeof(byte),
ropFastTransferDestinationConfigureResponse.OutputHandleIndex.GetType(),
3670,
@"[In RopFastTransferDestinationConfigure ROP Response Buffer]OutputHandleIndex (1 byte): An unsigned integer.");
// Add the debug information
Site.Log.Add(LogEntryKind.Debug, "Verify MS-OXCROPS_R3671");
// Verify MS-OXCROPS requirement: MS-OXCROPS_R3671
Site.CaptureRequirementIfAreEqual<byte>(
outputHandleIndex,
ropFastTransferDestinationConfigureResponse.OutputHandleIndex,
3671,
@"[In RopFastTransferDestinationConfigure ROP Response Buffer, OutputHandleIndex (1 byte):] This index MUST be set to the value specified in the OutputHandleIndex field in the request.");
// Add the debug information
Site.Log.Add(LogEntryKind.Debug, "Verify MS-OXCROPS_R3673");
// Verify MS-OXCROPS requirement: MS-OXCROPS_R3673
Site.CaptureRequirementIfAreEqual<Type>(
typeof(uint),
ropFastTransferDestinationConfigureResponse.ReturnValue.GetType(),
3673,
@"[In RopFastTransferDestinationConfigure ROP Response Buffer] ReturnValue (4 bytes): An unsigned integer.");
}